Toward Actionable Digital Twins for Radiation-Based Imaging and Therapy: Mathematical Formulation, Modular Workflow, and an OpenKBP-Based Dose-Surrogate Prototype
arXiv:2603.26820v1 Announce Type: cross Abstract: Digital twins for radiation-based imaging and therapy are most useful when they assimilate patient data, quantify predictive uncertainty, and support clinically constrained decisions. This paper presents a modular framework for actionable digital twins in radiation-based imaging and therapy and instantiates its reproducible open-data component using the \openkbpfull{} benchmark. The framework couples PatientData, Model, Solver, Calibration, and Decision modules and formalizes latent-state updating, uncertainty propagation, and chance-constraine — Hsin-Hsiung Huang, Bulent Soykan
View PDF HTML (experimental)
Abstract:Digital twins for radiation-based imaging and therapy are most useful when they assimilate patient data, quantify predictive uncertainty, and support clinically constrained decisions. This paper presents a modular framework for actionable digital twins in radiation-based imaging and therapy and instantiates its reproducible open-data component using the \openkbpfull{} benchmark. The framework couples PatientData, Model, Solver, Calibration, and Decision modules and formalizes latent-state updating, uncertainty propagation, and chance-constrained action selection. As an initial implementation, we build a GPU-ready PyTorch/MONAI reimplementation of the \openkbp{} starter pipeline: an 11-channel, 19.2M-parameter 3D U-Net trained with a masked loss over the feasible region and equipped with Monte Carlo dropout for voxel-wise epistemic uncertainty. To emulate the update loop on a static benchmark, we introduce decoder-only proxy recalibration and illustrate uncertainty-aware virtual-therapy evaluation using DVH-based and biological utilities. A complete three-fraction loop including recalibration, Monte Carlo inference, and spatial optimization executes in 10.3
s. On the 100-patient test set, the model achieved mean dose and DVH scores of 2.65 and 1.82Gy, respectively, with 0.58~s mean inference time per patient. The \openkbp{} case study thus serves as a reproducible test bed for dose prediction, uncertainty propagation, and proxy closed-loop adaptation, while future institutional studies will address longitudinal calibration with delivered-dose logs and repeat imaging.
Subjects:
Image and Video Processing (eess.IV); Computer Vision and Pattern Recognition (cs.CV); Applications (stat.AP); Computation (stat.CO)
Cite as: arXiv:2603.26820 [eess.IV]
(or arXiv:2603.26820v1 [eess.IV] for this version)
https://doi.org/10.48550/arXiv.2603.26820
arXiv-issued DOI via DataCite
Submission history
From: Hsin-Hsiung Huang [view email] [v1] Thu, 26 Mar 2026 22:37:18 UTC (142 KB)
Sign in to highlight and annotate this article

Conversation starters
Daily AI Digest
Get the top 5 AI stories delivered to your inbox every morning.
More about
researchpaperarxivKnowledge Map
Connected Articles — Knowledge Graph
This article is connected to other articles through shared AI topics and tags.
More in Research Papers

Quantum computers might crack today's encryption far sooner than we thought
According to a study by engineers at Caltech and the UC Department of Physics, quantum computers do not need to be nearly as powerful as previously believed to crack the most advanced cryptographic technologies. The research claims that Shor's algorithm could break RSA public-key encryption using quantum computers with just... Read Entire Article





Discussion
Sign in to join the discussion
No comments yet — be the first to share your thoughts!